Skip to Content
23 people viewing now
SKU: 1356 Verified Supplier

Fiber Optic Laryngoscope Set of 4 Blade

(0 review)
Cold Light Source No trauma causing hot bulb No electrical wires in the blade No electrical switches Full stainless steel construction No Flickering, No possibility of loose bulb entering oral airway For Medical Use Over 3000 fibers bundles togather enures steady, bright and focused beam. Matt finish Macintosh Fiber Optic Stainless Steel Laryngoscope Blades size are Optic fiber Laryngscope Blade size 1 for Infant Optic fiber Laryngscope Blade size 2 for Child, Optic fiber Laryngscope Blade size 3 for Adult, Optic fiber Laryngscope?Blade Size 4 for Large Adult. The curved design of the Macintosh Blade allows the tip to be guided to the epiglottic vallecula for direct visualization of the glottis whilst maintaining the tongue to the side for intubation. Application: Helps in intubation during the administration of general anaesthesia or for mechanical ventilation. Detects causes of voice problems, such as breathing voice, hoarse voice, weak voice, or no voice. Detects causes of throat and ear pain. Evaluates difficulty in swallowing : a persistent sensation of lump in the throat, or mucous with blood. Detects strictures or injury to the throat, or obstructive masses in the airway.
₹ 6,006.00 ₹ 6,006.00 (Tax included) ₹ 7,980.00

 |  HSN: 90189041 In Stock · Ships Now
24% OFF You save ₹1974

Bulk Pricing — B2B Rates

GST invoice · bulk PO accepted
2-5 pcs
₹5,148/pc
6-20 pcs
₹4,839/pc
21-40 pcs
₹4,633/pc
*Prices shown are exclusive of GST and shipping charges. Every bulk order gets dedicated support.
Request Bulk Quote
Estimated Delivery: Sat, 19 Sep – Mon, 21 Sep
Free shipping
on bulk orders
GST Invoiced,
PO Accepted
Secure
payment
Expert
support

The Fiber Optic Laryngoscope Set of 4 Blade is a reusable airway management instrument designed for clinicians performing endotracheal intubation in operating theatres, emergency departments, ICUs, and pre-hospital critical care settings. Engineered with fibre optic illumination technology, the set provides enhanced visualisation of the laryngeal inlet during direct laryngoscopy in adult airway procedures. The system is commonly used by anaesthesiologists, emergency physicians, intensivists, and trained paramedics where rapid airway access and controlled intubation are clinically required. Its stainless steel blade construction and autoclavable components support repeated use within institutional sterilisation workflows.

CLINICAL USE CONTEXT

The Fiber Optic Laryngoscope Set of 4 Blade is routinely utilised during elective and emergency airway management procedures requiring direct visualisation of the vocal cords prior to tracheal intubation. In operating theatres, anaesthesiologists use fibre optic laryngoscopy during induction of general anaesthesia for surgical airway control. In ICU and emergency department settings, the device assists clinicians managing respiratory compromise, trauma-related airway obstruction, or acute deterioration requiring ventilatory support. The multiple blade configuration supports varying patient anatomies and procedural requirements, while fibre optic illumination improves visibility in low-light clinical environments. The device may also be incorporated into emergency crash carts and advanced life support airway kits used by critical care transport teams and paramedics.

COMPARISON TABLE

FeatureFibre Optic LaryngoscopeConventional Bulb Laryngoscope
Illumination MethodFibre optic light transmissionDirect bulb illumination
Visual FieldReduced shadow formationMore shadowing near blade tip
Sterilisation WorkflowDetachable and autoclavable bladesDepends on bulb configuration
Blade DurabilityFewer exposed electrical componentsBulb area prone to wear
Clinical UsageOT, ICU, emergency airway managementGeneral airway management
Light Intensity ConsistencyMore uniform illuminationVariable with bulb condition
Maintenance RequirementsFibre bundle inspection requiredBulb replacement required
Preferred ByAnaesthesiologists and critical care cliniciansGeneral procedural use

FAQ 

1. Is this laryngoscope set suitable for emergency intubation procedures?

Yes, the set is commonly used in emergency airway management where rapid visualisation of the glottis is required for endotracheal intubation. Fibre optic illumination can assist clinicians in emergency departments, ambulances, and critical care units where ambient lighting conditions may vary.

2. Can the blades be sterilised between patient uses?

The blades are designed for institutional sterilisation workflows and are generally compatible with standard autoclave sterilisation protocols. Facilities should follow manufacturer instructions and their internal decontamination guidelines before reuse.

3. What types of clinicians typically use this device?

This laryngoscope set is intended for trained healthcare professionals including anaesthesiologists, emergency physicians, intensivists, respiratory therapists, and advanced airway-trained paramedics. Proper airway management training is essential prior to clinical use.

4. Does the set include multiple blade sizes?

Yes, the system includes four interchangeable blades to support different airway management requirements and patient anatomies. Multiple blade configurations are commonly used in hospitals to improve flexibility during routine and difficult airway procedures.

5. Is the device compatible with standard laryngoscope handles?

Most fibre optic laryngoscope blades are designed for compatibility with standard fibre optic handles used in hospital airway systems. Users should verify handle fitting specifications and illumination compatibility before procurement or clinical deployment.

SAFETY DISCLAIMER

This product is intended for use by trained medical professionals experienced in airway management and endotracheal intubation procedures. Users should verify compatibility with existing handles, sterilisation systems, and institutional airway protocols before clinical use. Follow all applicable hospital decontamination, sterilisation, and infection-control procedures after each patient use.

SpecificationDetails
Product NameFiber Optic Laryngoscope Set of 4 Blade
TypeFibre Optic Laryngoscope Set
Blade ConfigurationSet of 4 interchangeable blades
MaterialStainless Steel
Illumination TypeFibre Optic Illumination
ColourSilver
Usage TypeReusable
ApplicationAirway management and endotracheal intubation
Clinical SettingsOT, ICU, Emergency Department, Ambulance, Critical Care
CategoryAnaesthesia & Airway Management Equipment
Sterilisation CompatibilityAutoclavable components
Latex InformationLatex-free construction recommended for institutional airway protocols
Handle TypeStandard compatible laryngoscope handle
Intended UsersAnaesthesiologists, emergency physicians, intensivists
PackagingComplete set with 4 blades and handle

Battery

2 AA Battery (Not Included in the Kit )

Customers Also Viewed