1X1 Manifold

(0 review)
Manifold of 1X1 cylinder for Oxygen complete with Brass blocks, High-pressure copper pipe, Regulator (optional) Non-Return Valve, Pigtail pipe and angle fitting on wall.
₹ 9,000.00 ₹ 9,000.00 (Tax included) ₹ 11,700.00

 |  HSN: 90189099 In Stock · Ships Now
23% OFF You save ₹2700
Request Bulk Quote
Estimated Delivery: Mon, 03 Aug – Wed, 05 Aug
Free shipping
on bulk orders
7-day
returns
Secure
payment
Expert
support

The 1×1 MGPS oxygen manifold is a single-cylinder-to-single-outlet medical gas connection assembly designed for biomedical engineers, hospital infrastructure teams, and facility managers responsible for maintaining uninterrupted oxygen supply in clinical settings. Configured for use within a Medical Gas Pipeline System (MGPS), this manifold connects one oxygen cylinder directly to one distribution point, making it particularly suited to smaller healthcare facilities, satellite wards, dental operatories, and areas where a compact, dedicated gas supply node is required. The assembly includes a precision-machined brass block body, a high-pressure copper pigtail connection, an integrated non-return valve to prevent reverse gas flow, and angled wall-mount fittings for secure installation. An optional pressure regulator can be incorporated at the point of order, allowing the unit to be adapted for both regulated and unregulated pipeline configurations.

CLINICAL USE CONTEXT

In hospital infrastructure planning, the 1×1 oxygen manifold serves as the entry-level node in a cylinder-based MGPS, providing a dedicated, pressure-stable oxygen feed from a single D-type or B-type cylinder to a designated terminal unit or distribution line. This configuration is commonly deployed by biomedical engineers and hospital facilities teams in settings such as procedure rooms, isolation bays, minor operating theatres, and rural primary health centres where a full multi-bank manifold system is neither practical nor necessary. The non-return valve is a critical safety component in this assembly: it prevents retrograde gas flow back into the cylinder during pressure fluctuations or pipeline maintenance, a scenario of particular concern when anaesthesiologists or respiratory therapists are managing live gas supplies in adjacent clinical areas. In accordance with MGPS design principles, the high-pressure copper pigtail provides a rigid, vibration-resistant connection that minimises leak risk at the cylinder-to-manifold interface — an important consideration in any area where continuous oxygen delivery is clinically non-negotiable, such as post-anaesthesia care units (PACU) or emergency department resuscitation bays. Facilities opting for the optional regulator configuration gain the added capability of delivering gas at a controlled line pressure, enabling direct integration with bedside terminal outlets without the need for a separate pressure-reducing station.

FAQ

Q1. Is this manifold latex-free? Yes. The 1×1 manifold is constructed entirely from brass and copper components — there are no rubber or latex parts in the body, block, or pigtail assembly. This makes it suitable for installation in facilities that maintain a latex-controlled environment, including paediatric units and allergy-sensitive clinical areas.

Q2. What cylinder size or type is this manifold compatible with? This manifold is designed for standard medical oxygen cylinders commonly used in Indian hospital infrastructure, typically D-type or B-type cylinders. Before installation, the biomedical or facilities team should confirm that the cylinder valve outlet threading matches the manifold's pigtail connector specification to ensure a leak-free, compliant connection.

Q3. Can a pressure regulator be added to this manifold? Yes. A pressure regulator is available as an optional add-on at the time of order. When specified, the regulator is integrated into the assembly to step down cylinder pressure to a safe distribution line pressure, making the unit suitable for direct connection to terminal units or bedside outlets without a separate pressure-reducing valve.

Q4. Is this manifold suitable for installation in an ICU or operating theatre? The 1×1 manifold is appropriate for use in any clinical area that requires a single-point, cylinder-fed oxygen supply node within an MGPS — including satellite ICU bays, minor operating theatres, and procedure rooms. For high-consumption environments such as main OTs or multi-bed ICUs, a multi-bank manifold with automatic changeover functionality would typically be more appropriate to ensure supply continuity.

Q5. What standards or compliance requirements should be verified before installation? In India, medical gas pipeline installations should comply with the relevant provisions of the Bureau of Indian Standards (BIS) guidelines for MGPS and the NABH standards for hospital infrastructure where applicable. Installation must be carried out by a qualified biomedical engineer or MGPS-certified technician. Facilities should also verify that the manifold and associated pipework have been pressure-tested and leak-checked before commissioning in any patient care area.

SAFETY DISCLAIMER

This product is intended for installation and use by qualified biomedical engineers, MGPS-certified technicians, and trained medical facility personnel only — it is not suitable for use by unqualified individuals. Prior to installation, verify that all components are compatible with the existing pipeline infrastructure, cylinder valve type, and intended gas application. All installation, commissioning, and periodic maintenance activities must be conducted in accordance with the facility's institutional protocols and applicable national standards for medical gas pipeline systems.