2X2 Manifold

(0 review)
Manifold of 2x2 cylinder for Oxygen complete with Brass blocks, High-pressure copper pipe, Regulator (optional) Non-Return Valve, Pigtail pipe and angle fitting on wall. It is used for Medical purpose.
₹ 13,000.01 ₹ 13,000.01 (Tax included) ₹ 22,500.00

 |  HSN: 90189099 In Stock · Ships Now
42% OFF You save ₹9499
Request Bulk Quote
Estimated Delivery: Mon, 03 Aug – Wed, 05 Aug
Free shipping
on bulk orders
7-day
returns
Secure
payment
Expert
support

The 2×2 Manifold is a dual-bank medical gas manifold system designed to supply a continuous, uninterrupted flow of oxygen (or other medical gases) from two paired cylinders to a facility's piped gas network — making it an essential component in hospital Medical Gas Pipeline Systems (MGPS). It is intended for use by biomedical engineers, medical gas installation technicians, and hospital facility managers responsible for maintaining uninterrupted gas supply in operating theatres, intensive care units, and emergency departments. The manifold operates on an automatic changeover principle: when the primary bank of cylinders is depleted, gas supply seamlessly switches to the secondary bank, preventing any interruption to clinical gas delivery. Constructed with a brass block assembly, high-pressure copper pipework, non-return valves, and pigtail connections, the system meets the demands of continuous-duty clinical environments where gas supply failure is not clinically acceptable.

CLINICAL USE CONTEXT

In acute care environments, a reliable and continuously available oxygen supply underpins virtually every critical intervention — from mechanical ventilation in the ICU to anaesthetic gas delivery in the operating theatre. The 2×2 manifold is installed in dedicated cylinder manifold rooms and connects directly to the facility's MGPS network, ensuring that when one bank of oxygen cylinders reaches depletion, gas delivery continues uninterrupted from the standby bank without any manual intervention. This changeover capability is operationally critical in NICUs, where even a brief lapse in oxygen supply to a ventilator-dependent neonate carries serious clinical consequence, and in operating theatres where the anaesthesiologist depends on a stable pipeline pressure throughout a procedure. Biomedical engineers and MGPS commissioning technicians select dual-bank manifold configurations specifically to meet NABH (National Accreditation Board for Hospitals) and HTM 02-01–equivalent standards that mandate cylinder redundancy in life-critical gas supply. The non-return valves incorporated within the manifold assembly prevent backflow between banks, protecting both cylinder integrity and pipeline purity — a requirement stipulated in IS 3624 and relevant international medical gas piping standards.

COMPARISON TABLE

2×2 Manifold vs 1×1 (Single-Bank) Manifold

Feature2×2 Manifold (Dual Bank)1×1 Manifold (Single Bank)
No. of cylinders4 (2 per bank)2 (all on one bank)
Automatic changeoverYes — seamless bank switchoverNo — manual cylinder change required
Supply continuityUninterrupted during cylinder swapBrief interruption risk during changeover
Recommended settingICU, OT, NICU, high-dependency unitsLow-demand areas, small clinics
NABH / HTM complianceMeets redundancy requirementsMay not satisfy critical-area standards
Non-return valvesDual NRV (one per bank)Single NRV
Maintenance downtimeNear-zero (live bank remains active)Requires planned shutdown for cylinder change
Relative installation costModerate–highLower

FAQ

Q1: Is the 2×2 manifold latex-free? Yes. The 2×2 manifold assembly consists entirely of metallic components — brass manifold blocks, copper high-pressure pipework, and steel pigtail fittings — with no latex-containing parts anywhere in the assembly. As this product interfaces with the pipeline infrastructure rather than with patients directly, latex sensitivity is not a primary clinical concern, but the metal-only construction does confirm there is no latex present.

Q2: What cylinder valve connection does this manifold use, and is it compatible with standard Indian oxygen cylinders? The manifold uses pigtail flexible connectors with standard high-pressure cylinder valve fittings compatible with medical oxygen cylinders of the type widely used across Indian hospitals. Before installation, the commissioning technician should verify that the pigtail connector specification matches the cylinder valve outlet thread (typically BS 341 No. 3 for oxygen in India) to ensure a gas-tight, leak-free connection.

Q3: Does the 2×2 manifold include a pressure regulator? A pressure regulator is listed as optional on this configuration and is available on request. In most MGPS installations, a line pressure regulator is fitted downstream of the manifold assembly to reduce cylinder outlet pressure to the standard pipeline delivery pressure (typically 4 bar for oxygen). Procurement teams should confirm whether a regulator is required as part of the manifold assembly or whether it will be supplied and fitted separately as part of the wider MGPS installation.

Q4: Can this manifold be used for medical gases other than oxygen? The brass and copper construction of this manifold is appropriate for oxygen service, and depending on the specific configuration, it may be adapted for use with other non-flammable medical gases such as medical air or nitrous oxide — subject to compatibility verification with the installer. It is critical that the manifold assembly, including all seals and fittings, be confirmed suitable for the intended gas service before installation, as using oxygen-specific components with incompatible gases (or vice versa) can create a safety hazard.

Q5: What standards or certifications should a hospital check before procuring this manifold for an MGPS installation? For hospital procurement in India, the manifold and its installation should conform to the Bureau of Indian Standards specification for medical gas pipeline systems, and the overall MGPS installation should satisfy NABH accreditation requirements for medical gas infrastructure. Hospitals undergoing NABH assessment should confirm with their MGPS contractor that the manifold configuration meets the mandated cylinder redundancy and non-return valve requirements stipulated in the applicable standards, and that the installation is commissioned and certified by a qualified medical gas engineer.

SAFETY DISCLAIMER

This product is intended for installation and use by qualified biomedical engineers, medical gas system technicians, and trained hospital facility personnel only — it must not be installed or modified by untrained staff. Compatibility with the intended gas service, cylinder valve connection type, and downstream pipeline pressure must be verified by the installing engineer prior to commissioning. All installation, maintenance, and cylinder changeover procedures must be carried out in accordance with the facility's medical gas safety protocols and applicable national standards for medical gas pipeline systems.

SpecificationDetails
Product Name2×2 Manifold
SKU / Model No.1050
Configuration2 cylinders × 2 banks (dual bank, 4 cylinders total)
Primary MaterialBrass block body; high-pressure copper pipe headers
Gas CompatibilityOxygen (medical grade); compatible with other medical gases per installation design
Key ComponentsBrass manifold blocks, high-pressure copper pipe, non-return valves (NRV), pigtail flexible connectors, wall-angle fittings
RegulatorOptional (available on request)
Usage TypeMedical / Hospital MGPS installation
ApplicationMedical Gas Pipeline System (MGPS) cylinder manifold room
CategoryMedical Gas Pipeline System Accessories
Latex InformationNot applicable (no patient-contact components)
HSN Code90189099
PackagingStandard commercial packaging for bulk/hospital procurement