Single Stage Single Gauge Nitrous Oxide Regulator with preset outlet pressure of approx. 4.2 kgf/sq.cm. (60 lbs/sqin) and fitted safety valve
₹ 1,800.00 ₹ 1,800.00 (Tax included) ₹ 3,650.00

 |  HSN: 84818090 In Stock · Ships Now
50% OFF You save ₹1850
Request Bulk Quote
Estimated Delivery: Tue, 04 Aug – Thu, 06 Aug
Free shipping
on bulk orders
7-day
returns
Secure
payment
Expert
support

The Single Stage Nitrous Oxide Regulator is a precision medical gas control device designed for anaesthesia delivery systems, OT gas manifolds, and clinical gas administration setups in hospitals and surgical centres. Commonly used by anaesthesiologists, biomedical engineers, and critical care teams, the regulator ensures controlled outlet pressure from nitrous oxide cylinders during procedural sedation and inhalational anaesthesia applications. This regulator is typically integrated with central gas supply systems, anaesthesia workstations, and pipeline-compatible medical gas circuits where stable gas flow and pressure consistency are clinically important. Its single-stage pressure reduction mechanism supports routine use in operating theatres, emergency care units, and procedural suites requiring regulated nitrous oxide delivery.

CLINICAL USE CONTEXT

In clinical practice, a single-stage nitrous oxide regulator is used to reduce high cylinder pressure to a controlled working pressure suitable for anaesthesia machines and gas delivery systems. It is commonly utilised in operating theatres during inhalational anaesthesia procedures, dental sedation setups, and short procedural interventions requiring controlled analgesic gas administration. Anaesthesiologists and OT technicians rely on regulated nitrous oxide flow to maintain compatibility with anaesthesia workstations and gas manifolds. In emergency and trauma settings, the regulator may also support analgesia delivery systems where portable nitrous oxide cylinders are used. Biomedical maintenance teams routinely inspect these regulators to ensure pressure stability, leak prevention, and compliance with institutional gas safety protocols.

COMPARISON TABLE

FeatureSingle Stage Nitrous Oxide RegulatorDual Stage Nitrous Oxide Regulator
Pressure ReductionOne-stage pressure reductionTwo-stage sequential pressure reduction
Outlet Pressure StabilitySuitable for standard clinical useMore stable during cylinder depletion
Clinical SettingRoutine OT and procedural useAdvanced continuous-use applications
ComplexitySimpler mechanical designMore complex internal mechanism
Maintenance RequirementLower servicing complexityRequires more detailed servicing
Cost ConsiderationTypically lower procurement costHigher due to dual-stage mechanism
Cylinder Pressure CompensationModerateImproved consistency
Typical UsersHospitals, clinics, dental setupsHigh-dependency and specialised anaesthesia setups

FAQ 

1. What is a single-stage nitrous oxide regulator used for?

A single-stage nitrous oxide regulator is used to reduce high-pressure gas from a nitrous oxide cylinder into a controlled outlet pressure suitable for medical gas delivery systems. It is commonly connected to anaesthesia machines, sedation systems, and OT gas supply setups in hospitals and surgical centres.

2. Can this regulator be used with all nitrous oxide cylinders?

The regulator must only be used with compatible medical-grade nitrous oxide cylinders and approved connector standards. Healthcare facilities should verify thread type, inlet compatibility, and pressure specifications before installation to ensure safe operation.

3. Is this regulator suitable for continuous operating theatre use?

Yes, single-stage regulators are commonly used in routine operating theatre environments and procedural areas where stable gas pressure is required. However, clinical engineering teams should perform periodic inspection and leak testing as part of preventive maintenance protocols.

4. Does the regulator require sterilisation after use?

The regulator itself is not typically sterilised using autoclave methods unless specified by the manufacturer. External cleaning and decontamination should follow institutional biomedical equipment cleaning procedures and infection control guidelines.

5. What is the difference between a single-stage and dual-stage regulator?

A single-stage regulator reduces cylinder pressure in one step, making it suitable for standard clinical applications. Dual-stage regulators provide additional pressure stabilisation, particularly useful in environments where highly consistent outlet pressure is required over prolonged use.

SAFETY DISCLAIMER

This product is intended for use by trained medical professionals familiar with medical gas administration systems and anaesthesia equipment. Users should verify compatibility with cylinders, connectors, and downstream gas delivery devices before clinical use. Cleaning, inspection, and decontamination must follow institutional biomedical engineering and infection control protocols.

SpecificationDetails
Product NameSingle Stage Nitrous Oxide Regulator
Capacity/SizeStandard cylinder-compatible configuration
MaterialBrass body with corrosion-resistant finish
ColourMetallic finish
Usage TypeReusable
ApplicationMedical gas pressure regulation
CategoryMedical Gas Equipment
TypeSingle-stage gas regulator
Latex InformationLatex-free components not in patient contact pathway
PackagingIndividual unit packaging
Gas CompatibilityNitrous Oxide (N₂O)
Pressure ControlSingle-stage pressure reduction
Clinical Use AreaOT, ICU, emergency and procedural sedation units
Connection TypeCylinder-mounted configuration
Sterilisation RequirementExternal surface decontamination as per hospital protocol