Two Stage Two Gauge Oxygen Regulator

(0 review)
Stage of Pressure Regulation: Double Stage Pressure: High Pressure Relief Valve Pressure (Bar): 9 Equipment Class ( as per IS 6901: 2009 with latest amndmt1 Inlet Pressure to the Regulator,Max (Bar): 9 Operating and Storage Temperature Must be in range of -20 Degree C to + 60 Degree C) (Degree Celsius): yesOutlet Pressure to be controlled,Max (Bar): 9 Warranty (Years): 1 Indian Standard And Other Details Conformity to Indian Standard IS1 6901:2009 With Latest Amdmnt. Gas Oxygen Stage of Pressure Regulation: Double Stage Pressure High Pressure Material for Pressure Regulators ( Must Conforms to ISO 9539 ):BrassRelief Valve Pressure (Bar): 9 Equipment Class ( as per IS 6901: 2009 with latest amndmt:1 Flow Rate (m3/h):m3/h Type of Outlet Connection ( Must be in accordance with ISO3253): NA Gas Tightness shall confirms to ISO 5171:Yes Weight of Regulator (Grams):1000 No of Pressure Gauges Fitted:2Inlet Pressure to the Regulator,Max (Bar):9 Operating and Storage Temperature Must be in range of -20°C to +60°C) (Degree Celsius):yes Outlet Pressure to be controlled,Max (Bar): 9 Dimensions (LxWxD) (mm x mm x mm):300x150x150 Type of Inlet Connection ( (Must be in accordance with ISO/TR 7470):NA Warranty And Test Report Details Warranty (Years):1
₹ 3,450.00 ₹ 3,450.00 (Tax included) ₹ 4,500.00

 |  HSN: 84818090 In Stock · Ships Now
23% OFF You save ₹1050
Request Bulk Quote
Estimated Delivery: Wed, 17 Jun – Fri, 19 Jun
Free shipping
on bulk orders
7-day
returns
Secure
payment
Expert
support

The Two Stage Two Gauge Oxygen Regulator is a medical gas pressure control device designed for controlled oxygen delivery in hospitals, emergency care units, and ambulance systems. Engineered for clinicians, respiratory therapists, anaesthesiologists, and biomedical procurement teams, this double stage oxygen regulator supports stable outlet pressure during oxygen administration and gas-assisted clinical procedures. Manufactured in accordance with IS 6901:2009 and compliant with relevant ISO gas-tightness requirements, the regulator is intended for integration with medical oxygen cylinder systems used in ICU, OT, and respiratory support environments. Its dual gauge configuration enables simultaneous monitoring of cylinder pressure and regulated outlet pressure for controlled oxygen flow management.

CLINICAL USE CONTEXT

In clinical practice, a two stage oxygen regulator is used where stable oxygen pressure delivery is required despite fluctuations in cylinder pressure during prolonged administration. This configuration is commonly utilised in operation theatres during anaesthesia support, in intensive care units for ventilator-linked oxygen supply, and in emergency departments during high-dependency respiratory management. Anaesthesiologists and respiratory therapists rely on dual-stage regulation to minimise pressure variation during oxygen-assisted procedures and patient transport. In ambulance and trauma care settings, the dual gauge assembly allows paramedics to continuously monitor residual cylinder pressure while maintaining controlled outlet delivery. The brass regulator body and ISO-compliant gas tightness characteristics support routine use within central oxygen cylinder management protocols.

COMPARISON TABLE

FeatureTwo Stage Two Gauge Oxygen RegulatorSingle Stage Oxygen Regulator
Pressure StabilityMore consistent outlet pressureOutlet pressure may fluctuate
Gauge ConfigurationTwo gaugesUsually one or two gauges
Clinical ApplicationICU, OT, ventilator supportGeneral oxygen administration
Cylinder Pressure CompensationBetter compensation during depletionLimited compensation
Suitable for Prolonged UseYesModerate
Pressure Regulation MethodDouble stageSingle stage
Monitoring CapabilitySimultaneous inlet and outlet monitoringBasic monitoring
Preferred UsersAnaesthesiologists, respiratory therapistsGeneral ward staff

FAQ 

1. What is the advantage of a double stage oxygen regulator?

A double stage oxygen regulator reduces fluctuations in outlet pressure as the oxygen cylinder empties. This helps maintain more stable oxygen delivery in critical care environments where consistent pressure regulation is clinically important.

2. Can this regulator be used in ICU and OT settings?

Yes, this regulator is commonly used in intensive care units, operation theatres, and emergency response systems where oxygen cylinders are part of respiratory support infrastructure. The dual gauge design assists clinicians in monitoring both cylinder and delivery pressure during use.

3. Is the regulator compatible with medical oxygen cylinders?

The regulator is designed specifically for oxygen gas systems and conforms to applicable Indian and ISO standards referenced in the specifications. Compatibility with the cylinder valve and connector type should still be verified before installation.

4. What do the two gauges indicate?

One gauge typically displays cylinder pressure, allowing monitoring of remaining oxygen volume, while the second gauge indicates regulated outlet pressure. This arrangement assists healthcare professionals in maintaining controlled oxygen administration.

5. Can the regulator tolerate varying environmental temperatures?

Yes, the specified operating and storage temperature range is -20°C to +60°C. This allows the regulator to function across standard hospital environments, emergency transport systems, and controlled storage areas.

SAFETY DISCLAIMER

This oxygen regulator is intended for use by trained medical professionals and authorised clinical personnel only. Compatibility with oxygen cylinders, connectors, and downstream medical devices should be verified before clinical use. Follow institutional protocols for inspection, handling, sterilisation, and decontamination of medical gas equipment.

SpecificationDetails
Product NameTwo Stage Two Gauge Oxygen Regulator
CategoryMedical Gas Equipment
TypeDouble Stage Oxygen Pressure Regulator
MaterialBrass (Conforms to ISO 9539)
ColourBrass Finish
Usage TypeHospital / Clinical Use
ApplicationOxygen cylinder pressure regulation
Gas TypeOxygen
Number of Gauges2 Pressure Gauges
Pressure RegulationDouble Stage
Relief Valve Pressure9 Bar
Maximum Inlet Pressure9 Bar
Maximum Controlled Outlet Pressure9 Bar
Gas Tightness StandardConforms to ISO 5171
Equipment ClassAs per IS 6901:2009 with latest amendment
Operating Temperature-20°C to +60°C
Storage Temperature-20°C to +60°C
Dimensions300 × 150 × 150 mm
Weight1000 g
Outlet Connection TypeAs per ISO 3253
Inlet Connection TypeAs per ISO/TR 7470
Latex InformationLatex-Free Components Not Specified
PackagingSingle Unit
Warranty1 Year