The Two Stage Two Gauge Oxygen Regulator is a medical gas pressure control device designed for controlled oxygen delivery in hospitals, emergency care units, and ambulance systems. Engineered for clinicians, respiratory therapists, anaesthesiologists, and biomedical procurement teams, this double stage oxygen regulator supports stable outlet pressure during oxygen administration and gas-assisted clinical procedures. Manufactured in accordance with IS 6901:2009 and compliant with relevant ISO gas-tightness requirements, the regulator is intended for integration with medical oxygen cylinder systems used in ICU, OT, and respiratory support environments. Its dual gauge configuration enables simultaneous monitoring of cylinder pressure and regulated outlet pressure for controlled oxygen flow management.
CLINICAL USE CONTEXT
In clinical practice, a two stage oxygen regulator is used where stable oxygen pressure delivery is required despite fluctuations in cylinder pressure during prolonged administration. This configuration is commonly utilised in operation theatres during anaesthesia support, in intensive care units for ventilator-linked oxygen supply, and in emergency departments during high-dependency respiratory management. Anaesthesiologists and respiratory therapists rely on dual-stage regulation to minimise pressure variation during oxygen-assisted procedures and patient transport. In ambulance and trauma care settings, the dual gauge assembly allows paramedics to continuously monitor residual cylinder pressure while maintaining controlled outlet delivery. The brass regulator body and ISO-compliant gas tightness characteristics support routine use within central oxygen cylinder management protocols.
COMPARISON TABLE
| Feature | Two Stage Two Gauge Oxygen Regulator | Single Stage Oxygen Regulator |
|---|---|---|
| Pressure Stability | More consistent outlet pressure | Outlet pressure may fluctuate |
| Gauge Configuration | Two gauges | Usually one or two gauges |
| Clinical Application | ICU, OT, ventilator support | General oxygen administration |
| Cylinder Pressure Compensation | Better compensation during depletion | Limited compensation |
| Suitable for Prolonged Use | Yes | Moderate |
| Pressure Regulation Method | Double stage | Single stage |
| Monitoring Capability | Simultaneous inlet and outlet monitoring | Basic monitoring |
| Preferred Users | Anaesthesiologists, respiratory therapists | General ward staff |
FAQ
1. What is the advantage of a double stage oxygen regulator?
A double stage oxygen regulator reduces fluctuations in outlet pressure as the oxygen cylinder empties. This helps maintain more stable oxygen delivery in critical care environments where consistent pressure regulation is clinically important.
2. Can this regulator be used in ICU and OT settings?
Yes, this regulator is commonly used in intensive care units, operation theatres, and emergency response systems where oxygen cylinders are part of respiratory support infrastructure. The dual gauge design assists clinicians in monitoring both cylinder and delivery pressure during use.
3. Is the regulator compatible with medical oxygen cylinders?
The regulator is designed specifically for oxygen gas systems and conforms to applicable Indian and ISO standards referenced in the specifications. Compatibility with the cylinder valve and connector type should still be verified before installation.
4. What do the two gauges indicate?
One gauge typically displays cylinder pressure, allowing monitoring of remaining oxygen volume, while the second gauge indicates regulated outlet pressure. This arrangement assists healthcare professionals in maintaining controlled oxygen administration.
5. Can the regulator tolerate varying environmental temperatures?
Yes, the specified operating and storage temperature range is -20°C to +60°C. This allows the regulator to function across standard hospital environments, emergency transport systems, and controlled storage areas.
SAFETY DISCLAIMER
This oxygen regulator is intended for use by trained medical professionals and authorised clinical personnel only. Compatibility with oxygen cylinders, connectors, and downstream medical devices should be verified before clinical use. Follow institutional protocols for inspection, handling, sterilisation, and decontamination of medical gas equipment.
Alternative Products
These other products might interest you
| Specification | Details |
|---|---|
| Product Name | Two Stage Two Gauge Oxygen Regulator |
| Category | Medical Gas Equipment |
| Type | Double Stage Oxygen Pressure Regulator |
| Material | Brass (Conforms to ISO 9539) |
| Colour | Brass Finish |
| Usage Type | Hospital / Clinical Use |
| Application | Oxygen cylinder pressure regulation |
| Gas Type | Oxygen |
| Number of Gauges | 2 Pressure Gauges |
| Pressure Regulation | Double Stage |
| Relief Valve Pressure | 9 Bar |
| Maximum Inlet Pressure | 9 Bar |
| Maximum Controlled Outlet Pressure | 9 Bar |
| Gas Tightness Standard | Conforms to ISO 5171 |
| Equipment Class | As per IS 6901:2009 with latest amendment |
| Operating Temperature | -20°C to +60°C |
| Storage Temperature | -20°C to +60°C |
| Dimensions | 300 × 150 × 150 mm |
| Weight | 1000 g |
| Outlet Connection Type | As per ISO 3253 |
| Inlet Connection Type | As per ISO/TR 7470 |
| Latex Information | Latex-Free Components Not Specified |
| Packaging | Single Unit |
| Warranty | 1 Year |